LC2K0901E7
TeSys K reversing contactor - 3P - AC-3 <= 440 V 9 A - 1 NC - 48 V AC coil
Range: TeSys K Miniature Contactors FAQ Documents & Downloads-
Product availability :
Stock - Normally stocked in distribution facility
-
Characteristics
Main range of product TeSys Krange TeSysproduct name TeSys Kproduct or component type Reversing contactordevice short name LC2Kdevice application Controlcontactor application Motor controlResistive loadutilisation category AC-4AC-3AC-1device presentation Preassembled with reversing power busbarpoles description 3Ppole contact composition 3 NOSystem Voltage 690 V AC 50/60 Hz power circuit<= 690 V AC 50/60 Hz signalling circuit[Ie] rated operational current 9 A at <= 440 V AC AC-3 power circuit20 A (<= 122 °F (50 °C)) at <= 440 V AC AC-1 power circuit16 A (<= 158 °F (70 °C)) at 690 V AC AC-1 power circuitmotor power kW 4 kW at 380...415 V AC 50/60 Hz4 kW at 440 V AC 50/60 Hz4 kW at 480 V AC 50/60 Hz4 kW at 500...600 V AC 50/60 Hz4 kW at 660...690 V AC 50/60 Hz2.2 kW at 220...230 V AC 50/60 Hzcontrol circuit type AC 50/60 Hz[Uc] control circuit voltage 48 V AC 50/60 Hzauxiliary contact composition 1 NC[Uimp] rated impulse withstand voltage 8 kVovervoltage category III[Ith] conventional free air thermal current 20 A at <= 122 °F (50 °C) power circuit10 A at <= 122 °F (50 °C) signalling circuitIrms rated making capacity 110 A AC power circuit conforming to NF C 63-110110 A AC power circuit conforming to IEC 60947110 A AC signalling circuit conforming to IEC 60947rated breaking capacity 110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 60947110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947[Icw] rated short-time withstand current 20 A <= 50 °C >= 15 min power circuit90 A <= 122 °F (50 °C) 1 s power circuit85 A <= 122 °F (50 °C) 5 s power circuit80 A <= 122 °F (50 °C) 10 s power circuit60 A <= 122 °F (50 °C) 30 s power circuit45 A <= 122 °F (50 °C) 1 min power circuit40 A <= 122 °F (50 °C) 3 min power circuit80 A 1 s signalling circuit90 A 500 ms signalling circuit110 A 100 ms signalling circuitassociated fuse rating 25 A gG at <= 440 V power circuit25 A aM power circuit10 A gG signalling circuit conforming to IEC 6094710 A gG signalling circuit conforming to VDE 0660average impedance 3 mOhm at 50 Hz - Ith 20 A power circuit[Ui] rated insulation voltage 690 V signalling circuit conforming to IEC 60947-4-1690 V signalling circuit conforming to IEC 60947-5-1600 V signalling circuit conforming to UL 508600 V power circuit conforming to CSA C22.2 No 14600 V signalling circuit conforming to CSA C22.2 No 14690 V power circuit conforming to IEC 60947-4-1600 V power circuit conforming to UL 508electrical durability 0.18 Mcycles 20 A AC-1 at Ue <= 440 V1.3 Mcycles 9 A AC-3 at Ue <= 440 Vinterlocking type Mechanicalmounting support RailPlatestandards VDE 0660BS 5424IEC 60947NF C 63-110product certifications ULCSAconnections - terminals Screw clamp terminals 1 cable(s) 0...0.01 in² (1.5...4 mm²) - cable stiffness: solidScrew clamp terminals 1 cable(s) 0...0.01 in² (0.75...4 mm²) - cable stiffness: flexible - without cable endScrew clamp terminals 1 cable(s) 0...0 in² (0.34...2.5 mm²) - cable stiffness: flexible - with cable endScrew clamp terminals 2 cable(s) 0...0.01 in² (1.5...4 mm²) - cable stiffness: solidScrew clamp terminals 2 cable(s) 0...0.01 in² (0.75...4 mm²) - cable stiffness: flexible - without cable endScrew clamp terminals 2 cable(s) 0...0 in² (0.34...1.5 mm²) - cable stiffness: flexible - with cable endtightening torque 11.5 lbf.in (1.3 N.m) - on screw clamp terminals - with screwdriver Philips No 211.5 lbf.in (1.3 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mmoperating time 10...20 ms coil de-energisation and NO opening10...20 ms coil energisation and NO closingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 5 Mcyclesoperating rate 3600 cyc/hComplementary control circuit voltage limits 0.2...0.75 Uc at <= 122 °F (50 °C) drop-out0.8...1.15 Uc at <= 122 °F (50 °C) operationalinrush power in VA 30 VA at 68 °F (20 °C)hold-in power consumption in VA 4.5 VA at 68 °F (20 °C)heat dissipation 1.3 Wauxiliary contacts type Type instantaneous 1 NCsignalling circuit frequency <= 400 Hzminimum switching current 5 mA signalling circuitminimum switching voltage 17 V signalling circuitnon overlap distance 0.02 in (0.5 mm)insulation resistance > 10 MOhm signalling circuitEnvironment IP degree of protection IP20 conforming to VDE 0106protective treatment TC conforming to IEC 60068TC conforming to DIN 50016ambient air temperature for operation -13...122 °F (-25...50 °C)ambient air temperature for storage -58...176 °F (-50...80 °C)operating altitude 6561.68 ft (2000 m) without derating derating in temperatureflame retardance V1 conforming to UL 94Requirement 2 conforming to NF F 16-101Requirement 2 conforming to NF F 16-102mechanical robustness Shocks contactor closed, on X axis 10 Gn for 11 ms IEC 60068-2-27Shocks contactor closed, on Y axis 15 Gn for 11 ms IEC 60068-2-27Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on X axis 6 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on Y axis 10 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6Vibrations contactor opened 2 Gn, 5...300 Hz IEC 60068-2-6height 2.28 in (58 mm)width 3.54 in (90 mm)depth 2.24 in (57 mm)product weight 0.86 lb(US) (0.39 kg)Ordering and shipping details Category 22327 - CTR,K-LINE,AC,OPEN,REVDiscount Schedule I12GTIN 00785901908609Nbr. of units in pkg. 1Package weight(Lbs) 0.83000000000000007Returnability NCountry of origin FROffer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) Compliant - since 0706 - Schneider Electric declaration of conformity Schneider Electric declaration of conformityREACh Product environmental profile AvailableProduct end of life instructions AvailableContractual warranty Warranty period 18 months -
Documents and Downloads (1)