LC1K0910R7
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 440 V AC coil
Range: TeSys K Miniature Contactors FAQ Documents & Downloads-
Product availability :
Stock - Normally stocked in distribution facility
-
Characteristics
Main range of product TeSys Krange TeSysproduct or component type Contactorproduct name TeSys Kdevice application Controlcontactor application Resistive loadMotor controlComplementary utilisation category AC-4AC-1AC-3poles description 3Ppole contact composition 3 NO[Ie] rated operational current 9 A at <= 440 V AC AC-3 power circuit20 A (<= 122 °F (50 °C)) at <= 440 V AC AC-1 power circuit16 A (<= 158 °F (70 °C)) at 690 V AC AC-1 power circuitcontrol circuit type AC 50/60 Hz[Uc] control circuit voltage 440 V AC 50/60 Hzmotor power kW 2.2 kW at 400 V AC 50/60 Hz AC-42.2 kW at 220...230 V AC 50/60 Hz AC-34 kW at 380...415 V AC 50/60 Hz AC-34 kW at 440 V AC 50/60 Hz AC-34 kW at 480 V AC 50/60 Hz AC-34 kW at 500...600 V AC 50/60 Hz AC-34 kW at 660...690 V AC 50/60 Hz AC-3auxiliary contact composition 1 NOovervoltage category III[Ith] conventional free air thermal current 20 A at <= 122 °F (50 °C) power circuit10 A at <= 122 °F (50 °C) signalling circuitIrms rated making capacity 110 A AC power circuit conforming to NF C 63-110110 A AC power circuit conforming to IEC 60947110 A AC signalling circuit conforming to IEC 60947rated breaking capacity 110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 60947110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947associated fuse rating 25 A gG at <= 440 V power circuit25 A aM power circuit10 A gG signalling circuit conforming to IEC 6094710 A gG signalling circuit conforming to VDE 0660average impedance 3 mOhm at 50 Hz - Ith 20 A power circuitinsulation resistance > 10 MOhm signalling circuitinrush power in VA 30 VA at 68 °F (20 °C)hold-in power consumption in VA 4.5 VA at 68 °F (20 °C)heat dissipation 1.3 Wcontrol circuit voltage limits 0.2...0.75 Uc at <= 122 °F (50 °C) drop-out0.8...1.15 Uc at <= 122 °F (50 °C) operationaloperating rate 3600 cyc/hauxiliary contacts type Type instantaneous (1 NO)signalling circuit frequency <= 400 Hzminimum switching current 5 mA signalling circuitminimum switching voltage 17 V signalling circuitoperating time 10...20 ms coil de-energisation and NO opening10...20 ms coil energisation and NO closingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1non overlap distance 0.02 in (0.5 mm)mechanical robustness Shocks contactor closed, on X axis 10 Gn for 11 ms IEC 60068-2-27Shocks contactor closed, on Y axis 15 Gn for 11 ms IEC 60068-2-27Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on X axis 6 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on Y axis 10 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6Vibrations contactor opened 2 Gn, 5...300 Hz IEC 60068-2-6Environment product certifications CSAULprotective treatment TC conforming to IEC 60068TC conforming to DIN 50016operating altitude 6561.68 ft (2000 m) without derating in temperatureflame retardance V1 conforming to UL 94Requirement 2 conforming to NF F 16-101Requirement 2 conforming to NF F 16-102Ordering and shipping details Category 22326 - CTR,K-LINE,AC,OPEN,NONREVDiscount Schedule I12GTIN 00785901877769Nbr. of units in pkg. 1Package weight(Lbs) 0.40000000000000002Returnability NCountry of origin FROffer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) Compliant - since 0640 - Schneider Electric declaration of conformity Schneider Electric declaration of conformityREACh Product environmental profile AvailableProduct end of life instructions AvailableContractual warranty Warranty period 18 months -
Documents and Downloads (1)